Sign In | Join Free | My himfr.com
Home > DC Contactor >

Eaton contactor DLM12-01 coil voltage 24V AC rated power 5.5 kW

OUTER ELECTRONIC TECHNOLOGY (HK) LIMITED
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Eaton contactor DLM12-01 coil voltage 24V AC rated power 5.5 kW from wholesalers
     
    Buy cheap Eaton contactor DLM12-01 coil voltage 24V AC rated power 5.5 kW from wholesalers
    • Buy cheap Eaton contactor DLM12-01 coil voltage 24V AC rated power 5.5 kW from wholesalers
    • Buy cheap Eaton contactor DLM12-01 coil voltage 24V AC rated power 5.5 kW from wholesalers
    • Buy cheap Eaton contactor DLM12-01 coil voltage 24V AC rated power 5.5 kW from wholesalers
    • Buy cheap Eaton contactor DLM12-01 coil voltage 24V AC rated power 5.5 kW from wholesalers

    Eaton contactor DLM12-01 coil voltage 24V AC rated power 5.5 kW

    Ask Lasest Price
    Brand Name : Eaton
    Model Number : DLM12-04
    Price : Negotiations
    • Product Details
    • Company Profile

    Eaton contactor DLM12-01 coil voltage 24V AC rated power 5.5 kW

    Eaton contactor DLM12-01 coil voltage 24V AC rated power 5.5 kW

    PRODUCT SPECIFICATIONS

    Electrical connection type for auxiliary- and control-current circuit
    Screw connection
    Number of poles
    Three-pole
    10.10 Temperature rise
    The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
    10.11 Short-circuit rating
    Is the panel builder's responsibility. The specifications for the switchgear must be observed.
    10.12 Electromagnetic compatibility
    Is the panel builder's responsibility. The specifications for the switchgear must be observed.
    10.13 Mechanical function
    The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
    10.2.2 Corrosion resistance
    Meets the product standard's requirements.
    10.2.3.1 Verification of thermal stability of enclosures
    Meets the product standard's requirements.
    10.2.3.2 Verification of resistance of insulating materials to normal heat
    Meets the product standard's requirements.
    10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
    Meets the product standard's requirements.
    10.2.4 Resistance to ultra-violet (UV) radiation
    Meets the product standard's requirements.
    10.2.5 Lifting
    Does not apply, since the entire switchgear needs to be evaluated.
    10.2.6 Mechanical impact
    Does not apply, since the entire switchgear needs to be evaluated.
    10.2.7 Inscriptions
    Meets the product standard's requirements.
    10.3 Degree of protection of assemblies
    Does not apply, since the entire switchgear needs to be evaluated.
    10.4 Clearances and creepage distances
    Meets the product standard's requirements.
    10.5 Protection against electric shock
    Does not apply, since the entire switchgear needs to be evaluated.
    10.6 Incorporation of switching devices and components
    Does not apply, since the entire switchgear needs to be evaluated.
    10.7 Internal electrical circuits and connections
    Is the panel builder's responsibility.
    10.8 Connections for external conductors
    Is the panel builder's responsibility.
    10.9.2 Power-frequency electric strength
    Is the panel builder's responsibility.
    10.9.3 Impulse withstand voltage
    Is the panel builder's responsibility.
    10.9.4 Testing of enclosures made of insulating material
    Is the panel builder's responsibility.
    Fitted with:
    Mirror contact
    Varistor suppressor circuit
    Operating frequency
    9000 mechanical Operations/h (DC operated)
    Pollution degree
    3
    Climatic proofing
    Damp heat, constant, to IEC 60068-2-78
    Damp heat, cyclic, to IEC 60068-2-30
    Connection to SmartWire-DT
    In conjunction with DIL-SWD SmartWire DT contactor module
    Yes
    Rated impulse withstand voltage (Uimp)
    8000 V AC
    Utilization category
    AC-3: Normal AC induction motors: starting, switch off during running
    AC-1: Non-inductive or slightly inductive loads, resistance furnaces
    AC-4: Normal AC induction motors: starting, plugging, reversing, inching
    Connection
    Screw terminals
    Frame size
    FS1
    Ambient operating temperature - max
    60 °C
    Ambient operating temperature - min
    -25 °C
    Ambient operating temperature (enclosed) - max
    40 °C
    Ambient operating temperature (enclosed) - min
    -25 °C
    Ambient storage temperature - max
    80 °C
    Ambient storage temperature - min
    -40 °C
    Assigned motor power at 115/120 V, 60 Hz, 1-phase
    1 HP
    Assigned motor power at 200/208 V, 60 Hz, 3-phase
    3 HP
    Assigned motor power at 230/240 V, 60 Hz, 1-phase
    2 HP
    Assigned motor power at 230/240 V, 60 Hz, 3-phase
    3 HP
    Assigned motor power at 460/480 V, 60 Hz, 3-phase
    10 HP
    Assigned motor power at 575/600 V, 60 Hz, 3-phase
    10 HP
    Conventional thermal current Ith (1-pole, enclosed)
    45 A
    Conventional thermal current Ith (3-pole, enclosed)
    18 A
    Conventional thermal current Ith at 55°C (3-pole, open)
    21 A
    Conventional thermal current Ith of main contacts (1-pole, open)
    50 A
    Equipment heat dissipation, current-dependent Pvid
    1.5 W
    Heat dissipation capacity Pdiss
    0 W
    Heat dissipation per pole, current-dependent Pvid
    0.5 W
    Switching time (DC operated, make contacts, closing delay) - max
    31 ms
    Switching time (DC operated, make contacts, opening delay) - max
    12 ms
    Application
    Contactors for Motors
    Product category
    Contactors
    Protection
    Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
    Arcing time
    10 ms
    Electrical connection type of main circuit
    Screw connection
    Screwdriver size
    0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
    2, Terminal screw, Pozidriv screwdriver
    Voltage type
    DC
    Degree of protection
    IP20
    Number of auxiliary contacts (normally closed contacts)
    1
    Number of auxiliary contacts (normally open contacts)
    0
    Number of contacts (normally closed contacts)
    1
    Number of contacts (normally closed) as main contact
    0
    Number of contacts (normally open contacts)
    0
    Number of main contacts (normally open contact)
    3
    Operating temperature - max
    60 °C
    Operating temperature - min
    -25 °C
    Power consumption (pick-up) at DC
    4.5 W
    Power consumption (sealing) at DC
    4.5 W
    Rated breaking capacity at 220/230 V
    120 A
    Rated breaking capacity at 380/400 V
    120 A
    Rated breaking capacity at 500 V
    100 A
    Rated breaking capacity at 660/690 V
    70 A
    Rated control supply voltage (Us) at AC, 50 Hz - max
    0 V
    Rated control supply voltage (Us) at AC, 50 Hz - min
    0 V
    Rated control supply voltage (Us) at AC, 60 Hz - max
    0 V
    Rated control supply voltage (Us) at AC, 60 Hz - min
    0 V
    Contact configuration
    1 NC
    Drop-out voltage
    At least smoothed two-phase bridge rectifier or three-phase rectifier
    0.6 - 0.15 x UC, DC operated
    Overvoltage category
    III
    Duty factor
    100 %
    Emitted interference
    According to EN 60947-1
    Interference immunity
    According to EN 60947-1
    Lifespan, mechanical
    10,000,000 Operations (DC operated)
    Pick-up voltage
    0.85 - 1.1 V DC x Uc (only with auxiliary contact module with 3 or more N/C contacts)
    0.8 - 1.1 V DC x Uc
    0.7 - 1.3 V DC x Uc (without auxiliary contact module and at ambient air temperature + 40 °C)
    Safe isolation
    400 V AC, Between the contacts, According to EN 61140
    400 V AC, Between coil and contacts, According to EN 61140
    Screw size
    M3.5, Terminal screw
    Switching capacity (auxiliary contacts, general use)
    1 A, 250 V DC, (UL/CSA)
    10 A, 600 V AC, (UL/CSA)
    Switching capacity (auxiliary contacts, pilot duty)
    A600, AC operated (UL/CSA)
    P300, DC operated (UL/CSA)
    Terminal capacity (flexible with ferrule)
    1 x (0.75 - 2.5) mm²
    2 x (0.75 - 2.5) mm²
    Shock resistance
    7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
    5.7 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
    10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
    5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
    3.4 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
    3.4 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
    Terminal capacity (solid)
    2 x (0.75 - 2.5) mm²
    1 x (0.75 - 4) mm²
    Terminal capacity (solid/stranded AWG)
    Single 18 - 10, double 18 - 14
    Switching capacity (main contacts, general use)
    20 A, Maximum motor rating (UL/CSA)
    Tightening torque
    1.2 Nm, Screw terminals
    Rated control supply voltage (Us) at DC - max
    24 V
    Rated control supply voltage (Us) at DC - min
    24 V
    Rated insulation voltage (Ui)
    690 V
    Rated making capacity up to 690 V (cos phi to IEC/EN 60947)
    168 A
    Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
    22 A
    Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
    12 A
    Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
    12 A
    Rated operational current (Ie) at AC-3, 440 V
    12 A
    Rated operational current (Ie) at AC-3, 500 V
    10 A
    Rated operational current (Ie) at AC-3, 660 V, 690 V
    7 A
    Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V
    7 A
    Rated operational current (Ie) at AC-4, 400 V
    7 A
    Rated operational current (Ie) at AC-4, 440 V
    7 A
    Rated operational current (Ie) at AC-4, 500 V
    6 A
    Rated operational current (Ie) at AC-4, 660 V, 690 V
    5 A
    Rated operational current (Ie) at DC-1, 110 V
    20 A
    Rated operational current (Ie) at DC-1, 220 V
    15 A
    Rated operational current (Ie) at DC-1, 60 V
    20 A
    Rated operational current for specified heat dissipation (In)
    12 A
    Rated operational power at AC-3, 240 V, 50 Hz
    4 kW
    Rated operational power at AC-3, 380/400 V, 50 Hz
    5.5 kW
    Rated operational power at AC-3, 415 V, 50 Hz
    7 kW
    Rated operational power at AC-4, 220/230 V, 50 Hz
    2 kW
    Rated operational power at AC-4, 240 V, 50 Hz
    2.2 kW
    Rated operational power at AC-4, 380/400 V, 50 Hz
    3 kW
    Rated operational power at AC-4, 415 V, 50 Hz
    3.4 kW
    Rated operational power at AC-4, 440 V, 50 Hz
    3.6 kW
    Rated operational power at AC-4, 500 V, 50 Hz
    3.5 kW
    Rated operational power at AC-4, 660/690 V, 50 Hz
    4.4 kW
    Rated operational power (NEMA)
    7.4 kW
    Rated operational voltage (Ue) at AC - max
    690 V
    Resistance per pole
    4.6 mΩ
    Static heat dissipation, non-current-dependent Pvs
    4.5 W
    Stripping length (control circuit cable)
    10 mm
    Stripping length (main cable)
    10 mm
    Short-circuit current rating (basic rating)
    5 kA, 45 A max. fuse, SCCR (UL/CSA)
    5 kA, 45 A max. CB, SCCR (UL/CSA)
    Short-circuit current rating (high fault at 480 V)
    100 kA, 45 A CLASS J max. fuse, SCCR (UL/CSA)
    30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA)
    Short-circuit current rating (high fault at 600 V)
    100 kA, 45 A CLASS J max. fuse, SCCR (UL/CSA)
    30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA)
    Short-circuit protection rating (type 1 coordination) at 400 V
    35 A gG/gL
    Suitable for
    Also motors with efficiency class IE3
    Short-circuit protection rating (type 1 coordination) at 690 V
    25 A gG/gL
    Short-circuit protection rating (type 2 coordination) at 400 V
    20 A gG/gL
    Short-circuit protection rating (type 2 coordination) at 690 V
    20 A gG/gL
    Special purpose rating of ballast electrical discharge lamps
    20 A (480V 60Hz 3phase, 277V 60Hz 1phase)
    20 A (600V 60Hz 3phase, 347V 60Hz 1phase)
    Special purpose rating of definite purpose rating
    12 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
    72 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
    Special purpose rating of elevator control
    2 HP, 240 V 60 Hz 3-ph, (UL/CSA)
    7.5 HP, 480 V 60 Hz 3-ph, (UL/CSA)
    11 A, 480 V 60 Hz 3-ph, (UL/CSA)
    2 HP, 200 V 60 Hz 3-ph, (UL/CSA)
    6.8 A, 240 V 60 Hz 3-ph, (UL/CSA)
    7.5 HP, 600 V 60 Hz 3-ph, (UL/CSA)
    9 A, 600 V 60 Hz 3-ph, (UL/CSA)
    7.8 A, 200 V 60 Hz 3-ph, (UL/CSA)
    Special purpose rating of refrigeration control (CSA only)
    60 A, LRA 480 V 60 Hz 3phase; (CSA)
    10 A, FLA 480 V 60 Hz 3phase; (CSA)
    60 A, LRA 600 V 60 Hz 3phase; (CSA)
    10 A, FLA 600 V 60 Hz 3phase; (CSA)
    Special purpose rating of resistance air heating
    20 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
    20 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
    Special purpose rating of tungsten incandescent lamps
    14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
    14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
    Operating temperature
    -25° to 60°C
    Conventional thermal current Ith at 40°C (3-pole, open)
    22 A
    Conventional thermal current Ith at 50°C (3-pole, open)
    21 A
    Conventional thermal current Ith at 60°C (3-pole, open)
    20 A
    Rated operational power at AC-3, 440 V, 50 Hz
    7.5 kW
    Rated operational power at AC-3, 500 V, 50 Hz
    7 kW
    Rated operational power at AC-3, 690 V, 50 Hz
    6.5 kW
    Actuating voltage
    24 V DC
    Altitude
    Max. 2000 m
    Operating voltage at AC, 50 Hz - min
    24 V
    Operating voltage at AC, 50 Hz - max
    690 V
    Operating voltage at AC, 60 Hz - min
    24 V
    Operating voltage at AC, 60 Hz - max
    690 V





    Quality Eaton contactor DLM12-01 coil voltage 24V AC rated power 5.5 kW for sale